Current article

Calculation of Capacity of Vertically Loaded RC Joint of Local Transf er from Square Column to Straight Wall


ZHONG Shu sheng,XIAO De zhou,WANG Fei

DOI:10.11835/j.issn.1674-4764.2001.04.008

Received ,Revised December 17, 2000, Accepted , Available online July 01, 2015

Volume ,2001,Pages 40-47

  • Abstract
On the basis of experimental results on four specimens of vertically loaded RC joints of local transfer from square column to straight wall, interaction between the transfer beam and the straight wall above it is analyzed. In the test, the effect of height of armpit on the transfer beam upon the behavior of the joint is specially studied. As a result, determination of the design shear force and shear capacity of the transfer beam and calculation of capacity of the straight wall are suggested, taking into account the effect of shear span ratio of the beam.