Steady state Heat Transfer Performance of Domestic Light frame Wood Wall
WANG Xiao huan,FEI ben hua,ZHOU hai bin and REN hai qing
DOI:10.11835/j.issn.1674-4764.2010.04.015
Received December 25, 2009,Revised , Accepted , Available online July 01, 2015
Volume ,2010,Pages 76-79
- Abstract
Steady state heat transfer performance is an important indicator for wood wall to assess its energy efficiency performance. Based on the introduction of foreign advanced technology of wood residence, 13 different wall specimens were manufactured using domestic materials in this study, and the effective heat transfer coefficient were measured by hot box heat flow meter test method. With the results from theoretical calculation, it was found that the effective heat transfer coefficient of walls were between 0.226~0.529 W/(m2· K). The thermal level was IIt for specimen 1,2,3, and 6, and level It was for the others, which could be appropriate for the severe cold areas and meet the requirements of 65% Energy efficiency standard in China. The calculation results were in good agreement with the measured ones.