Current article

Performance of Drainage Reuse as Waterscape Treated by Combinational Technique of Biologic Contact Oxidation and Constructed Wetland


HU Xue bin,CHAI Hong xiang,PENG Shu juan and LONG Teng rui

DOI:10.11835/j.issn.1674-4764.2009.06.020

Received August 26, 2009,Revised , Accepted , Available online July 01, 2015

Volume ,2009,Pages 112-116

  • Abstract
The high grade gray water was pre treated by biologic contact oxidation on load of 0.72 KgBOD5·m-3·d-1, and then post treated by constructed wetland. On the basis of experiment, it was found that: Totle nitrogen (TN) was the restrictive index of the combinational technique. To meet the reclaimed water quality standard and reuse for waterscape, the peak hydraulic load of constructed wetland was 0.50 m·d-1 in summer (30~36 ℃), and 0.33 m·d-1 in winter (8~12 ℃). And the load ratio of the peak hydraulic under the summer and winter conditions was 3:2. With the experimental results and reclaimed water quantity requirements in different seasons of buildings, treatment scale can be determined.